Skip to product information
SikaShield® W159 ED 1.5mm
$86.20
Sale price
$86.20
Regular price
SikaShield® W159 ED 1.5mm
A polymer modified bituminous waterproofing membrane wet-applied to concrete using adhesive mortar SikaShield® W1. Flame-free installation makes it safe for confined spaces. Reinforced with cross-laminated PE film for high mechanical performance. Fully bonded and watertight against lateral water migration. Can be applied on wet concrete.
Overview
Specifications
| Property | Value | Standard |
|---|---|---|
| Type | Polymer modified bituminous waterproofing membrane (wet-applied) | – |
| Reinforcement | Cross-laminated Polyethylene (PE) | – |
| Effective Thickness | 1.5 mm ±0.15 mm | – |
| Roll Width | 1.0 m | – |
| Roll Length | 20.0 m (20 m² per roll) | – |
| Top & Bottom Surface | Removable foil liner | – |
| Foldability at Low Temperature | Unaffected at −25°C | – |
| Resistance to Static Puncture | 240 N ±10% | ASTM E154 |
| Tensile Strength | 3 N/mm² ±10% | ASTM D412 |
| Elongation | 300% ±10% | ASTM D412 |
| Resistance to Tear | 30 N ±10% | ASTM D624 |
| Joint Peel Resistance | 400 N/m ±10% (at +23°C) | ASTM D1876 |
| Permeability to Water Vapour | 0.008 g/m²/24hr/mm-Hg ±10% | ASTM E96 |
| Resistance to Lateral Water Migration | 70 m ±7 m | ASTM D5385/D5385M |
| Ambient Temperature | +5°C min / +50°C max | – |
| Relative Humidity | Max. 80% | – |
| Shelf Life | 12 months from date of production | – |
| Storage | Dry, +5°C to +35°C, vertical position, original packaging | – |
Usage
- Basements and below-ground structures
- Vertical reinforced concrete walls
- Single and strip foundations
- Single layer under heavy protection
- Base sheet in multi-layer waterproofing systems
- Note: Not suitable for roofs permanently exposed to UV radiation
Advantages
- No-torch application – safe for confined spaces
- Fully bonded system for reliable waterproofing
- Watertight against lateral water migration (70 m resistance)
- Can be applied on wet concrete
- Fast and easy installation
- Flame-free application
- Requires minimal surface preparation
- High impact resistance (240 N static puncture)
Packaging
- 1 roll = 1.0 m wide × 20.0 m long (20 m²)
Colour
- Top and bottom surface: Removable foil liner
Product Details
Product Information
| Property | Detail |
|---|---|
| Composition | Polymer modified bitumen with cross-laminated PE reinforcement |
| Effective Thickness | 1.5 mm ±0.15 mm |
| Shelf Life | 12 months from date of production |
| Storage Conditions | Dry, +5°C to +35°C, stored vertically, do not stack pallets |
Application
Application Information
| Parameter | Value |
|---|---|
| Ambient Temperature | +5°C min / +50°C max |
| Substrate Temperature | +5°C min / +50°C max |
| Relative Humidity | Max. 80% |
| Side Overlap | Min. 100 mm |
| End Overlap | Min. 150 mm |
| Curing before backfilling | Min. 24 hours at +25°C |
| Backfilling deadline | Within 7 days after application |
Application Steps
- Substrate Preparation: Apply adhesive mortar SikaShield® W1 onto the water-saturated concrete substrate while still wet. Refer to the SikaShield® W1 PDS for full substrate condition requirements.
- Alignment: Unroll the membrane and align it. Re-roll before application. Lay membranes parallel to avoid coinciding joints. When applying over another bituminous membrane, straddle the overlaps of the previous layer.
- Wet Application: Lay the membrane directly over the wet adhesive mortar. At one end, peel away part of the release liner from the underside. Bond this end to the adhesive and substrate. Continue peeling the liner sideways while bonding the rest of the membrane.
- Rolling: Roll the applied membrane surface with a roller from the centre to the edge to remove air bubbles. Push any excess adhesive towards the opposite direction of the sealed side overlap.
- Overlap Sealing: If ambient temperature is below +10°C, seal membrane overlaps by heating with a gas torch or hot air to ensure proper adhesion and prevent adhesive trapping under the overlap.
- Curing & Backfilling: Allow adhesive mortar to cure for at least 24 hours at +25°C before backfilling. Complete backfilling within 7 days of application.
- Detailing: Use a sharp knife to cut around internal/external corners, upstands, vent pipes, drains, and support metalwork. Refer to the relevant method statement for detailing guidance.
- Footwear: Use flat-profile footwear only – spikes or sharp protrusions may puncture the membrane.