Skip to product information
Sika Waterbar® O VN
$128.00
Sale price
$128.00
Regular price
Sika Waterbar® O VN
A flexible thermoplastic PVC waterstop designed to stop water migration through construction and expansion joints in concrete structures. The multi-rib profile creates impenetrable barriers and sealing begins as soon as the concrete hardens. Available in 4 widths to suit all application types. Can be easily site-welded.
Overview
Specifications
| Property | Value | Standard |
|---|---|---|
| Material | Flexible thermoplastic PVC | – |
| Colour | Yellow | – |
| Shore A Hardness | >70 | ASTM D2240 |
| Tensile Strength | 12 N/mm² (±5%) | ASTM D412-06 |
| Elongation | 300% (±5%) | ASTM D412-06 |
| Service Temperature | −35°C to +55°C | – |
| Chemical Resistance (permanent) | Seawater, sewage | – |
| Chemical Resistance (temporary) | Diluted inorganic alkalis, mineral acids, mineral oils and fuels | – |
| Shelf Life | 5 years from date of production | – |
| Storage | Dry, shaded place, protected from sunlight | – |
System Sizes
| Type | Width (mm) ±5mm | Roll Length (m) | Nominal Thickness (mm) ±10% |
|---|---|---|---|
| O-15 | 150 | 20 | 3.0–4.5 |
| O-20 | 200 | 20 | 3.0–4.5 |
| O-25 | 250 | 20 | 3.0–4.5 |
| O-32 | 320 | 15 | 3.0–8.0 |
Usage
- Basements and below-ground structures
- Water reservoirs and swimming pools
- Sewage treatment plants
- Retaining walls and lift shafts
- Tunnels, culverts, and service pits
Advantages
- Sealing starts as soon as concrete has hardened
- Multi-rib profile provides impenetrable barriers to water migration
- Can be easily site-welded (welding knife available)
- Good chemical resistance to seawater, sewage, and diluted acids/alkalis
- Available in various profiles and sizes for all application types
Packaging
- O-15, O-20, O-25: 20 m rolls
- O-32: 15 m rolls
Colour
- Yellow flexible strip
Product Details
Product Information
| Property | Detail |
|---|---|
| Material | Flexible thermoplastic PVC |
| Shelf Life | 5 years from date of production |
| Storage Conditions | Dry, shaded place, protected from direct sunlight |
Application
Application Steps
- Positioning: Position the Sika Waterbar® O VN centrally within the construction or expansion joint, ensuring the centre bulb or ribs are correctly aligned with the joint plane.
- Fixing: Secure the waterstop in position using wire ties or clips to the reinforcement to prevent displacement during concrete pouring.
- Concrete Placement: Pour and compact concrete carefully on both sides of the waterstop. Ensure full encapsulation without voids or honeycombing around the waterstop profile.
- Site Welding: Where joints or connections are required, weld sections together using a welding knife. Ensure clean, even welds for a watertight connection.
- Inspection: After concrete has hardened, inspect the joint area to confirm the waterstop is correctly embedded and no voids are present.